Low Leakage Active Limiter
Text Box:

Low Leakage Active Limiter

S2D Microwave, Inc. reserves all the rights to change any specification without notice..

Environmental Rating

¨ Operating Temperature: -40°C to +85°C

¨ Storage Temperature: -65°C to +125°C

¨ Shock: MIL-STD-202F, Method 213B Cond B (75G, 6msec)

¨ Vibration: MIL-STD-202F, Method 204D Cond B (15G)

¨ Humidity: MIL-STD-202F, Method 103B Cond B (96 hours at 95% R.H.)

¨ Altitude: MIL-STD-202F, Method 105C Cond B (50,000 feet)

¨ Temperature Cycle: MIL-STD-202F, Method 107D Cond A (5 cycles)

S3

General Specifications

¨ Wide frequency range from 5 MHz to 65 GHz

¨ Power handling from 1W CW to 50W CW

¨ Low Insertion Loss

¨ Low Leakage

¨ In Built DC Blocking Cap

¨ Recovery time less than 10us

¨ Excellent VSWR

¨ Available in compact rugged packages

¨ Hermetic sealing option available

Text Box: 	       Microwave

S2D

LOW LEAKAGE  ACTIVE LIMITER PERFORMANCE MATRIX

DC +5V @10mA Typ Required

Note: We design and develop per customer requirement. Please contact factory.

MODEL

FREQUENCY RANGE GHz

MAX INSERTION LOSS dB

MAX VSWR dB

TYP LIM THRESHOLD dBm

NOM LEAKAGE @ 1W CW INPUT dBm

PACKAGE STYLE

LU10105

0.1 - 0.5

0.6

1.4

-10  TO +4

-10 TO +5

 

LU1011

0.1 - 1.0

0.6

1.4

-10  TO +4

-10 TO +5

LU1012

0.1 - 2.0

0.7

1.4

-10  TO +4

-10 TO +5

LU1014

0.1 - 4.0

0.8

1.5

-10  TO +4

-10 TO +5

LU10112

0.1 - 12

2.4

1.6

-10  TO +4

-10 TO +5

LU10114

0.1 - 14

2.5

1.6

-10  TO +4

-10 TO +5

LU10118

0.5 - 18

3.2

2.2

-10  TO +4

-10 TO +5

LU1052

0.5 - 2.0

0.7

1.4

-10  TO +4

-10 TO +5

LU1054

0.5 - 4.0

0.8

1.4

-10  TO +4

-10 TO +5

LU1056

0.5 - 6.0

1.2

1.4

-10  TO +4

-10 TO +5

LU10512

0.5 - 12

2.4

1.6

-10  TO +4

-10 TO +5

LU10516

0.5 - 16

1.7

1.6

-10  TO +4

-10 TO +5

LU10518

0.5 - 18

3.2

2.2

-10  TO +4

-10 TO +5

LU112

1.0 - 2.0

0.7

1.4

-10  TO +4

-10 TO +5

LU114

1.0 - 4.0

0.8

1.5

-10  TO +4

-10 TO +5

LU116

1.0 - 6.0

1.2

1.5

-10  TO +4

-10 TO +5

LU1112

1.0 - 12

2.4

1.6

-10  TO +4

-10 TO +5

LU1114

1.0 - 14

2.5

1.6

-10  TO +4

-10 TO +5

LU1116

1.0 - 16

1.8

1.7

-10  TO +4

-10 TO +5

LU1118

1.0 - 18

3.2

2.2

-10  TO +4

-10 TO +5

LU124

2.0 - 4.0

0.8

1.4

-10  TO +4

-10 TO +5

LU128

2.0 - 8.0

2

1.5

-10  TO +4

-10 TO +5

LU1212

2.0 - 12

2.4

1.6

-10  TO +4

-10 TO +5

LU1218

2.0 - 18

3.2

2.2

-10  TO +4

-10 TO +5

LU1612

6.0 - 12

2.4

1.8

-10  TO +4

-10 TO +5

LU1618

6.0 - 18

3.2

2.2

-10  TO +4

-10 TO +5

LU1713

7.0 - 13

2.5

1.6

-10  TO +4

-10 TO +5

LU1816

8.0 - 16

2.9

1.7

-10  TO +4

-10 TO +5

LU1818

8.0 - 18

3.2

2.2

-10  TO +4

-10 TO +5

LU11018

10 - 18

3.2

2.2

-10  TO +4

-10 TO +5